The installation of spray tower and washing tower equipment must be carried out in strict accordance with the standards, otherwise the equipment will be damaged in operation, and the treatment of industrial waste gas will not meet certain emission standards, thus reducing production efficiency and causing cost waste and environmental pollution.

I. Suggestions on installation of washing tower equipment for spray tower 1. When the spray tower leaves the factory, it will be packed and transported in sections according to the specific situation, and technicians will go to the site to install and debug it.

2. Pay attention to the processing and quantity calculation of construction materials, and try to save steel pipes. Generally speaking, the size of steel pipes is six meters. Be sure to mark the pipeline when processing, which will save time when installing equipment.

3. When installing the spray tower and washing tower, the equipment should be placed on the concrete above 150mm from the ground. The water pump and fan required by the equipment also need to be built with concrete foundation.

4. In addition, it should be noted that if the washing tower of the spray tower needs to be installed outdoors, it is necessary to pay attention to the anti-freezing measures of the bottom pool of the tower to avoid damage to the equipment caused by the temperature drop in winter.

Before installation and use of spray tower and washing tower equipment, it is necessary to carefully check whether the power distribution is correct and prohibit personnel from approaching. In addition, make sure that the tail gas pipeline is unblocked.

Second, the debugging and use precautions of the spray tower washing tower must be carried out in strict accordance with the operation process of the equipment during use to avoid damage to the equipment due to wrong operation mode.

First of all, when using the spray tower to wash the tower, you should first turn on the circulating water pump and let it run for 2-3 minutes before starting the blower. Stop, also should stop the fan 1-2 minutes, and then stop the circulating water pump.

Secondly, the acidity depth of the liquid in the bottom tank and the gas purification degree of the exhaust port should be checked regularly according to the use situation. Once it exceeds the standard, it should be replaced immediately.

It is worth noting that the spray tower washing tower equipment must be thoroughly overhauled after being used for one and a half to two years. At the same time, the packing of disc nozzles and fillers must be checked and cleaned every month.