Current location - Trademark Inquiry Complete Network - Trademark registration - Aidelong air-condition trademark
Aidelong air-condition trademark
〓K- 1000 operating instructions

1: Model setting steps:

1) brand+model automatic search function:

This "brand+model" automatic search mode is the fastest and most convenient search method.

Find out the brand code corresponding to the air conditioning brand from the brand model code table. Press the brand key for more than three seconds, and the brand code will start to increase at intervals of 1 second. When the display code is the brand code corresponding to the air conditioner, release it. At this point, the brand code has been set.

Automatically search for the corresponding model in the corresponding brand after selecting the brand. Press and hold the model key for more than three seconds, and the model code will start to increase, with an interval of 1 second, and a power-on code will be issued. When the air conditioner is turned on, it means that the corresponding code has been found, and at the same time, the model key is released to exit the model code search, and the setting is complete.

Check whether the buttons of the remote control work normally. If not, repeat this step until the most suitable code is found.

2) Manual search function: First press and hold the setting key for 2 seconds, and the model display will start flashing. At this time, press the select+ key and add 1 once to change the model, and at the same time transmit a remote control signal. Press the select key once, decrease 1 to change the model, and send a remote control signal at the same time. At the same time, observe whether the air conditioner responds. If the air conditioner turns on automatically, please stop running, and then press Enter to finish the setting.

If there is a corresponding model from the model comparison table, you can quickly search for the model. First, press and hold the setting key for 2 seconds, and the model display will start flashing. At this point, press and hold the Select+ key for 3 seconds to rapidly increase the model until the required signal is found, and then stop pressing the key. At this time, remote control signals can be transmitted to control the air conditioner. Long press the select key also has this function. Press Enter to exit the change of model status.

Check whether the buttons of the remote control work normally. If not, repeat this step until the most suitable code is found.

3) Automatic search mode:

1. First, press and hold the setting key for 2 seconds, and the model display will start flashing. Press the on/off button for a long time, the model will increase by 1 every two seconds, and the power-on code will be automatically issued. Release the key to stop transmission. Press the set key or confirm key to exit.

2. Press and hold the ON/OFF key for 6 seconds to enter the state of automatic power-on code, and the model will increase by 1 every two seconds. Stop after sending all startup codes, or press on/off, set key and confirm key to exit.

Check whether the buttons of the remote control work normally. If not, repeat this step until the most suitable code is found.

2. Clock setting steps:

Press the clock button to enter the clock setting state, and the clock flashes. Use temperature+or temperature-to adjust the current time. 10 seconds later, automatically exit the set time or press the clock button again to push out.

3: Timing on/off setting steps:

When using this model for the first time, you must send the code once to have the on-off function.

Press the timed shutdown button once, and the timed shutdown will increase by one hour. If it exceeds 24 hours, the scheduled shutdown will be cancelled. The displayed scheduled shutdown time indicates that the air conditioner is turned off after the set time. The displayed shutdown time will count down with time.

The setup steps for timed startup are the same as those for timed shutdown.

Switching timing adopts the hour system, and the maximum timing is 24 hours. Timing switching time cannot be the same, and if they are the same, no code will be sent. The maximum timing time depends on the timing time of the original remote control.

When setting the time switch, the remote controller sends a code to use the time switch function of the original machine.

If the remote controller does not send a code when setting the time switch machine, it will enter the time switch machine function. When the time is up, the remote controller sends out an on-off code. If the time switch machine time is the same, send a power-off code. (Note, pay attention to the state of the air conditioner at this time, because some remote controllers have the same on-off code, and the remote controllers should face the direction of the air conditioner).

By turning the machine on and off, the time switch machine can be removed.

3.3. Reset and Hold Functions

After reset, this remote control still keeps the original model.

K- 1000 brand model code list

Brand code application brand model code brand code application brand model code.

1 Haier 1- 19 2 1 Liangyu388

2 Gree 20-39 Meiling 389-390

3 Midea 40-59 Ningbo Wellcome 39 1-392

4 Changhong 60-79 Qixing 393

5 Kochi 80-99 days Kay 394

6 Huabao 100- 109 Rijiang 395-397

Kelon110-119 Risuo 398-399

7 TCL 120- 139 shamei 400

8 Galanz 140- 149 Xing Shan 40 1-402

Chunlan 170- 179 Shang Ling 403-409

9 Hualing 150- 169 Shang Ling 404406407

10Ox 180- 19922 Sic Bo 4 10-4 1 1

1 1 sanzuan 190 victory wind 4 12

Changfeng 190 Shengfeng Flying Deer 4 13

Shinco 200-209 Shuaikang414

12 aucma 2 10-229 Shuangling 4 15

13 Hisense 230-239 Shuanglu 4 16-4 18

Feilu 240-249 Songxing 4 19

14 Dongbao 250-269 Suohua 420

Dongxinbao 260-268 Soybean 42 1-422

15 Xinfei 270-279 Swan 423

GLEE 280 Tianjin air conditioning 424

Huawei 28 1 Tianyuan 425-428

Johnson 282 23 Tongli 429-430

KT02 _ D00 1 283 Wanbao431-433

KT02 _ D002 284 Power supply 434-443

KTY 00 1 285 Witley 444

KTY002 286 Fog Peak 445-446

KTY003 287 Shima 447

KTY004 288 24 West Leng 448-449

KTY005 289 Xianke 450-452

16 star, Boeing, Xinhua Bao 290 Little Swan 453

Sogou 29 1 Duckling 454-456

SOVA 292 Xinle 457-460

Ai Delong 293-295 Xinling461

Aite 296-299 and 462-463 stars

Ollie 300 Panda 464-466

Aoke 30 1-30225 Yangzi 467-47 1

Si Nuo 299 Mayao 472

Gao Shida 303 Electrolux 473-474

Beijing Jingdian 304 Yan Ying 475-483

Polka 305-306 26 Yutu 484-490

Bole 307 Zhengzhou Jinda 49 1-492

Doctor Gao 308-309 Zhong Yi 493

17 doctor 3 10 Jordan 494

Caixing 3 1 1 mobile phone 499

Changling 3 12-32327 Sanyo 500-529

Chengyuan/Maintenance Board 324 nec 500-529

Chuanghua 325-328 28 Mitsubishi 530-589

18 Venus 329 29 LG 590-599

Great Venus 330 Samsung 30 600-6 19

Thumb 33 1 3 1 Toshiba 620-639

Daewoo 332-333 32 Hitachi 640-659

Winter and Summer 334-335 33 Panasonic

Du Nan 336 Music 660-690

Gao 337-34 1 34 operator 690-699

Geer 342-343 Fujitsu 700-709

Guqiao 34435 Neitian 707,701709,

926-929

Everbright 345-346 Bang Sun 770,771

Hongyi 347 36 Daikin 7 10-729

Gao Hua 348 37 exactly 730-749

19 Huake 349-350 Shengbao 730-750

Huamei 35 1-35238 Whirlpool 750-753

Yellow River 353 York 754-756

HSBC 354-356 McVeigh 757-758

Toyo HSBC 357AKIRA 760

Le Jia 358 klimatair 76 1-762

Jiangnan air-condition 359KRIS 763

Jester 360 Roland -SEBO 764-765

Jin Beijing 36 1-362 JAL 766

Jinsong 363-365 Xitiao Electrician 767-769

Konka 366-367 39 Senbao 770-77 1

20 uni-AIR 368-369 teco 772-773

Li Kang 368-370 dongyang 1 774

Ranbo 37 1-383 dongyang 2 775

Lehua 384-385 Paddy Field 776-777

Li Ke 386-387 Changfu, Changgu 778-779

Liangyu 780

Jiang Cheng, Ji Chuan, Jin Meng, Keming, Cole, Dupard, Franbao, Lange, Orrin, Yi Tong, Xiamen University, Yidazhou, Meidian, Yi Ming, Gewei, Geyang, Dongao, Feipu, etc. 495-499, 759, 782-999.

4 1 or above air conditioner model code If you can't find the correct brand code, please use automatic search to find it, set the brand code to 0, and then press the model key to select 0-999. The setup process may take a long time, so please be patient.